Performance Analysis of 3 kWp Rooftop Grid-connected Solar Photovoltaic System in an Urban House of Southern India

Authors

  • V. Karuppasamy Vikraman Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India. Author
  • D. Praveen Kumar Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India. Author
  • R. Mahendiran Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India. Author

DOI:

https://doi.org/10.52151/jae2020571.1704

Keywords:

PV electricity, grid-connected PV system yields, system efficiency, capacity factor

Abstract

Energy performance of a 3 kWp solar photovoltaic (PV) system installed on the roof of an urban house in Coimbatore, India was evaluated. Performance indices as electricity output, system yields, performance ratio, system efficiency, and capacity factor were assessed from January 2017 to December 2017. The rooftop PV system supplied 4047 kWh of electricity to the grid during the year 2017 with a monthly average electricity output of 337.25 kWh. Annual average final yield compared with different PV systems in India was found to be 3.7 h.day-1. The analysis showed that the average PV system efficiency was 10.94 per cent. The performance ratio and capacity factor of the PV system were 0.72 and 15.41 %, respectively. The results could be used as a benchmark for the evaluation of photovoltaic systems in regions with similar climate.

Author Biographies

  • V. Karuppasamy Vikraman, Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India.

    P.G. Research Scholar

  • D. Praveen Kumar, Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India.

    P.G. Research Scholar

  • R. Mahendiran, Department of Renewable Energy Engineering, Agricultural Engineering College and Research Institute, Tamil Nadu Agricultural University, Coimbatore-641003, Tamil Nadu, India.

    Associate Professor

References

Al-Otaibi A. 2015. Performance evaluation of photovoltaic systems on Kuwaiti school’s rooftop. Energy Convers. Manage., 95, 110-119.

Antonio L; Steven H. 2003. Handbook of Photovoltaic Science and Engineering. John Wiley and Sons Ltd., ISBN:0-471-49196-9, 984-1043.

Attari K; Elyaakoubi A; Asselman A. 2016. Performance analysis and investigation of a grid-connected photovoltaic installation in Morocco. Energy Rep., 2, 261-266.

Central Electricity Authority. 2019. All India Installed Capacity, Monthly Report, December 2019, Government of India. http://www.cea.nic.in/monthlyinstalledcapacity.html.

Doolla S; Banerjee R. 2010. Diffusion of grid connected PV in India: An analysis of variations in capacity factor. In:Proc. 35th IEEE Photovoltaic Specialists Conference (PVSC), Berlin, 2349-2352.

Hairat M K; Gosh S. 2017. 100 GW solar power in India by 2022-A critical review. Renewable Sustainable Energy Rev., 73, 1041-1050.

Kumar S B; Sudhakar K. 2015. Performance evaluation of 10 MW grid connected solar photovoltaic power plant in India. Energy, 1, 184-192.

Kymakis E; Kalykakis S;Papazoglou T M. 2009. Performance analysis of a grid connected photovoltaic park on the island of Crete. Energy Convers. Manage., 50, 433-438.

Maghami M R; Hizam H; Gomes C; Radzi M A; Rezadad M I; Hajighorbani S. 2016. Power loss due to soiling on solar panel: A review. Renewable Sustainable Energy Rev., 59, 1307-1316.

Makade R G; Chakrabarti S; Jamil B; Sakhale C N. 2020. Estimation of global solar radiation for the tropical wet climatic region of India: A theory of experimentation approach. Renew. Energy., 146, 2044-2059.

Padmavathi K; Daniel A S. 2013. Performance analysis of a 3 MWp grid connected solar photovoltaic power plant in India. Energy Sustainable Dev., 17, 615-625.

Pundir K S; Varshney N; Singh G K. 2016. Comparative study of performance of grid connected solar photovoltaic power system in IIT Roorkee campus. In: Proc. International Conference on Innovative Trends in Science, Engineering and Management, New Delhi, 22-31.

Sharma R; Goel S. 2017. Performance analysis of a 11.2 kWp roof top grid-connected PV system in Eastern India. Energy Rep., 3, 76-84.

Sharma V; Chandel S S. 2013. Performance analysis of a 190 kWp grid interactive solar photovoltaic power plant in India. Energy, 55, 476-485.

Yadav S K; Bajpai U. 2018. Performance evaluation of a rooftop solar photovoltaic power plant in Northern India. Energy Sustainable Dev., 43, 130-138.

Published

2020-03-31

Issue

Section

Regular Issue

How to Cite

V. Karuppasamy Vikraman, D. Praveen Kumar, & R. Mahendiran. (2020). Performance Analysis of 3 kWp Rooftop Grid-connected Solar Photovoltaic System in an Urban House of Southern India. Journal of Agricultural Engineering (India), 57(1), 56-62. https://doi.org/10.52151/jae2020571.1704