Design of Tapered Drip Irrigation Pipes Non-Uniform Slopes

Authors

  • V Ravikumar Assistant Professor, Agricultural Engineering College, Kumulur, Lalgudi, Trichy, India - 621 712. Author
  • K Renuka Former graduate student, Agricultural Engineering College, Kumulur, Lalgudi, Trichy, India - 621 712, Author
  • CR Ranganathan Professor, College of Agricultural Engineering, Coimbatore, India 641003. Author

DOI:

https://doi.org/10.52151/jae2003403.1047

Abstract

Drip irrigation system design approach with tapered pipe segments (multi-diameter pipe segments) in a lateral or submain is a cost effective method. A new simple design method has been developed using Energy Gradient Line Approach (EGL) for the tapered pipes in non-uniform slopes. A non-uniform slope tapered pipe flow problem is divided into a series of uniform slope and uniform diameter pipe flow subproblems. An equation for determining the dripper discharge rates to determine the discharges of drippers for an uniform slope and uniform diameter pipe, with the flow occurring through drippers and also through the pipe beyond the last dripper, has been developed. The dripper discharges for each subproblem are considered as independent samples and the variation of discharges for the total pipe length is found out using the statistical equations. This method is demonstrated with a numerical problem and the results are compared with the step by step method of finding discharge rate in each dripper. This method has many advantages than the only manual method of Wu (1984), reported in the literature.

Downloads

Download data is not yet available.

References

Anwar AA. 1999. Factor G for pipelines with equally spaced multiple outlets and outflow 1. Irrig. and Drain. Engg., ASCE, 125(1):34-39.

Anwar AA. 2000. Adjusted average correction factors for sprinkler laterals. 1. Irrig. And Drain. Engg., ASCE, 126(5):296-303.

Bralts VF, I Pai Wu Gitlin HM. 1980. Manufacturing Variation and Drip Irrigation Uniformity. Transactions of ASAE, 23(1): 113-119.

Bralts VF; I Pai Wu Gitlin HM. 1981. Drip Irrigation uniformity considering emitter plugging. Transactions of ASAE, 24(6): 1234-1240.

Ravikumar. V, Bosu SS, Kumar V. 2001. Drip Irrigation System Design by energy gradient line approach for non-uniform outflow. Agricultural Engineering Journal, 10(3&4): 181-190.

Ravikumar V; Ranganathan CV; Bosu SS. 2003. Analytical equation for variation of discharge in drip irrigation laterals. J. Irrig. and Drain. Engg., ASCE, 129(4). (in press)

Wu I Pai, Gitlin HM.1974. Drip Irrigation design based on uniformity. Transactions of ASAE, 17(3):429-432.

Wu I Pai; Gitlin HM. 1975. Energy gradient line for drip irrigation laterals. 1. Irrg. and Drain. Engg., ASCE, 101(4):323-326.

Wu I Pai; Gitlin HM. 1977. Design of drip irrigation lines with varying pipe sizes Transactions of ASAE, 20(3): 522-528.

Wu I Pai; Gitlin HM. 1979. "Drip irrigation design on non-uniform slopes". J. Irrg. And Drain.Engg., ASCE, 105(3),289-303.

Wu I Pai. 1984. A uniplot method for drip irrigation lateral and submain design. Transactions of ASAE, 27(3): 522-528.

Published

2003-09-30

Issue

Section

Regular Issue

How to Cite

V Ravikumar, K Renuka, & CR Ranganathan. (2003). Design of Tapered Drip Irrigation Pipes Non-Uniform Slopes. Journal of Agricultural Engineering (India), 40(3), 63-73. https://doi.org/10.52151/jae2003403.1047